Suspends all cable listings to ul 2196 fire resistive fire resistant and circuit integrity cables ul has recently conducted research on a wide array of current products and systems originally certified under ul 2196 tests for fire resistive cables and ulc s139 standard method of fire test for evaluation.
Fire resistive cable system.
Fire resistive cables fire resistive conductors and components shall be tested and listed as a complete system shall be designated for use in a specific fire rated system and shall.
Ul certifies four new fire resistive cable systems.
A cable and components used to ensure survivability of critical circuits for a specified time under fire conditions.
Fire resistive fire resistant and circuit integrity cables are primarily installed in mixed occupancy high rise buildings tunnels bridges and other commercial infrastructures.
Fhit 40a and fhit7 40a for use as cic cable installation follows fhit 40a fhit7 40a and comtran s installation instructions.
Hr horizontal 1 hr vertical fire resistive cable for use in electric circuit integrity system no.
X is the size of the cable in awg or kcmil y is the size of the cable in mm2.
First a concern was brought to ul s attention that when fire resistive cables were installed in conduit with a zinc coating the circuit integrity was compromised by a reaction of the zinc with the copper conductors lowering.
Tratos has comprehensive modern fire testing facilities on site to ensure cable integrity.
This is commonly known as a circuit integrity ci cable and is 2 hour fire rated.
These 2 hour fire resistance rated systems are intended to be used in applications where conductors used for transmitting system information are required to remain operational during a fire.
Refer to r27557 fire resistive cable ul vitalink brand type fplr ci st1 cmr ci ls cl3r ci st1 for use in system no.
What are fire resistive or fire rated cables.
The definition of a fire resistive or fire rated cable is a cable that will continue to operate in the presence of a fire.
In many circumstances the referenced systems exist in conjunction with other fire mitigation system options which are not in question.
See ul fire resistance directory r19359 mm yr 3ft notes.
For use as ci cable installation follows the nec and local code.
The company can supply a complete range of fire resistant cables to comply with the latest standards and codes of practice covering fire detection alarm systems emergency lighting or other vital power supplies.
We test assemblies to international standards establishing an hourly rating to provide evidence of compliance to code requirements.
Or 2 hr fire resistive cable for use in elec tric circuit integrity system no.
Refer to installation instructions for hardware certifications.
Fire resistance rated designs are used to achieve code compliant installations where the building codes require hourly rated designs.